The Effect of Segment Number Variations on Dosimetric Quality and Monitor Unit Requirements in IMRT Planning for Rectal Cancer

Risna Kirana Rokar, Eko Hidayanto, Catur Edi Widodo, Sanggam Ramantisan, Ridho Almareanta, Rahmat Putra Pamungkas

Abstract


Variations in segment configurations in Intensity-Modulated Radiation Therapy (IMRT) can affect dosimetric quality and Monitor Unit (MU) requirements. This study aimed to analyze the effects of four configurations, namely S5, S10, S15, and Sliding Window (default/SSW), on target, organ-at-risk (OAR), and MU parameters in IMRT planning for rectal cancer. This retrospective dosimetric study included 10 patients and generated 40 plans calculated using the Eclipse Treatment Planning System (TPS) (6 MV photons, 50 Gy in 25 fractions, and a fixed grid resolution of 2.5 mm). The evaluated parameters were PTV V95%, Conformity Index (CI), Homogeneity Index (HI), Dmax, Bladder V50, Small Bowel V45, and MU. Data were analyzed using the Friedman test with Kendall’s W as the effect size, followed by two-sided Wilcoxon tests with Holm correction at α = 0.05. Significant differences were found in PTV V95%, CI, HI, Dmax, and MU (p < 0.001; W = 0.708–1.000), but not in Bladder V50 (p = 0.840; W = 0.028) or Small Bowel V45 (p = 0.172; W = 0.167). SSW yielded the highest mean V95% (99.482%) and CI (0.952), as well as the lowest HI (0.044) and Dmax (5265.22 cGy), but required the highest MU (995.70). S15 required 841.60 MU, which was 15.48% lower than SSW, with a V95% difference of only 0.036 percentage points. Therefore, S15 may be considered a potential compromise between dosimetric quality and MU requirements, subject to verification of OAR dose constraints and treatment-delivery quality assurance.

Keywords


rectal cancer; Intensity-Modulated Radiation Therapy; segment variation; dosimetry; Eclipse TPS; Monitor Unit.

Full Text:

PDF

References


Tali, T. A., Amin, F., Dar, J. A., Khan, N. A., & Khan, A. A. (2023). Dosimetric comparison of rectal carcinoma radiation therapy using three dimensional conformal radiation therapy and intensity modulated radiation therapy: An analytical observational study. International Journal of Community Medicine and Public Health, 10(8), 2933–2937. https://doi.org/10.18203/2394-6040.ijcmph20232146

Hayashi, T., Ogita, M., Nozawa, Y., Minamitani, M., & Yamashita, H. (2026). Comparison of small bowel and bladder doses between prone and supine positions in preoperative intensity-modulated radiotherapy for rectal cancer. Radiological Physics and Technology, 19(2), 771–781. https://doi.org/10.1007/s12194-026-01051-z

Abdulameer, M. S., et al. (2024). Dosimetric effect of collimator rotation on intensity modulated radiotherapy and volumetric modulated arc therapy for rectal cancer radiotherapy. Journal of X-Ray Science and Technology, 32(5), 1331–1348. https://doi.org/10.3233/XST-240172

Shi, J., Kong, F., Lu, M., Chen, J., He, G., & Li, Z. (2024). Effect of minimum monitor unit per dynamic control point on intensity-modulated radiation therapy planning dose distribution for liver cancer. Radiation Physics and Chemistry, 222, 111849. https://doi.org/10.1016/j.radphyschem.2024.111849

Ren, S., He, J., Han, S., Xu, N., Wang, W., Zhu, S., et al. (2026). Impact of field number and monitor units per segment on magnetic resonance-guided hypofractionated stereotactic radiotherapy for brain metastases: Plan quality, deliverability, and robustness trade-offs. Quantitative Imaging in Medicine and Surgery, 16(7), 561. https://doi.org/10.21037/qims-2025-1-2798

Brunner, T. B., Boda-Heggemann, J., Bürgy, D., et al. (2024). Dose prescription for stereotactic body radiotherapy: General and organ-specific consensus statement from the DEGRO/DGMP Working Group Stereotactic Radiotherapy and Radiosurgery. Strahlentherapie und Onkologie, 200, 737–750. https://doi.org/10.1007/s00066-024-02254-2

International Commission on Radiation Units and Measurements. Prescribing, Recording, and Reporting Photon-Beam Intensity-Modulated Radiation Therapy (IMRT). ICRU Report 83. 2010.

Bentzen, S. M., et al. Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): An Introduction to the Scientific Issues. International Journal of Radiation Oncology, Biology, Physics. 2010;76(3 Suppl):S3–S9.

McNiven, A. L., Sharpe, M. B., & Purdie, T. G. A new metric for assessing IMRT modulation complexity and plan deliverability. Medical Physics. 2010;37(2):505–515.

Srivastava, S. P., Cheng, C.-W., & Das, I. J. The dosimetric and radiobiological impact of calculation grid size on head and neck IMRT. Practical Radiation Oncology. 2017;7(3):209–217.




DOI: http://dx.doi.org/10.52155/ijpsat.v60.1.8895

Refbacks

  • There are currently no refbacks.


Copyright (c) 2026 risna kirana rokar

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.